Recent Jobs For Linn's Plumbing

Bryan N.

April 28, 2025 | Wellston, OK

We then drained the old 40-gal tank and removed it. We then retrofitted the gas, water, drains and ventilation. We installed the tankless unit, and everything is working properly and leak free.

Peggy B.

April 25, 2025 | Cushing, OK

Installed customer supplied kitchen sink faucet, Installed 2 customer supplied lavatory faucet, traps and supply lines. Tested and everything working properly.

Eddie B.

April 25, 2025 | Davenport, OK

Installed Delta shower valve, with chrome cover plate to cover old 2-handle shower valve. Caulked both cover plates. Tested and everything working properly.

Darla c.

April 24, 2025 | Shawnee, OK

Installed 5- customer supplied faucets, set dishwasher, garbage disposal and stainless-steel bar sink. Tested and everything working properly.

Jackson B.

April 23, 2025 | Davenport, OK

Installed new Delta tub and shower valve. Installed new 32” Delta tub and walls.

Elaine I.

April 23, 2025 | Chandler, OK

installed the new Lav faucet with new supply lines and pop up assembly.

Judy E.

April 22, 2025 | Meeker, OK

Flushed Navien tankless water heater for 1 hour, tested and everything working properly.

April 22, 2025 | Prague, OK

Replaced 20 gallon pressure tank, boiler drain, 40/60 pressure switch and pressure gauge. Tested and everything working properly.

Bill R.

April 22, 2025 | Chandler, OK

Replaced 50 gallon electric water heater, tested and everything working properly.

Rick H.

April 22, 2025 | Meeker, OK

After investigating we found that a repair on the wall hydrant was not possible. We had to take down a couple of areas of lattice on the back porch and move a large garden bed in order to crawl under the add on and finally make it to an access ...

Kathy H.

April 21, 2025 | Cushing, OK

Installed customer provided 40 gallon natural gas water heater. 3/4 inch galvanized lines coming into water heater adapted from galvanized to pex. Ran Pex to the water heater with new water shut off added a new gas shut off valve and supply line added pan and drain for pan. Also add a ...

Terry L.

April 21, 2025 | Prague, OK

Bathtub upstairs not draining pulled waste and overflow and noticed that stopper was not on there. Ran cable down and caught stopper on cables and pulled out of drain after pulling it out. Ran water in bathtub for several minutes to make sure everything was draining properly.

Gail G.

April 21, 2025 | Chandler, OK

Installed new shower head, cartridge and valve.

Dalton M.

April 18, 2025 | Beggs, OK

Installed sewer line with clean out, Installed Aerobic tank with sprinkler lines. Installed electrical wiring and tied into control box and disconnect. Set timer, tested system. Everything works. Raised control box and air compressor. Added 12” risers on the system.

Josh W.

April 17, 2025 | cushing, OK

Installed the water heater with a pan. Ran the vent out of the roof. Tested no leaks.

Total: 48